Backplane module to acquire liquid propulsion system’s sensor data

Requirements:

  • 24-bit ADC

    • External clock ADC - would be nice

  • 4 sensors (live telemetry would be nice):

    • Chamber Thermocouple - K-type thermocouple

    • Tank Thermocouple - K-type thermocouple

    • Chamber Transducer - Trafag NAT 8252.XXXXXX3219XX

      • Does not need live telemetry

    • Tank Transducer - Trafag NAT 8252.XXXXXX3219XX

      • Needs live telemetry (at least on the ground)

  • Local data storage at the rate of at least 10 samples per second per sensor

    • 1000SPS preferable

 

NOTES:

 

TO DO:

Identify suitable ADC: AD4111 for pressure sensors; 2x MAX31856MUD+ for thermocouples