Introduction

The power module is responsible for distributing power to the rest of the backplane and therefore requires little software for successful operation. However, power distribution can be monitored and provide valuable insight into the backplane's behaviors.   

This page reflects the software design for the second revision of the sensor module

Data

NameDataTypeSize (bytes)Sample Rate (Hz)
INA219 (3v3)

Voltage

Power

Current

float

float

float

32

32

32

15
INA219 (5v0)

Voltage

Power

Current

float

float

float

32

32

32

15
INA219 (BATT)

Voltage

Power

Current

float

float

float

32

32

32

15


*** If I did my math right, 15 hertz assuming a default 12-bit resolution for the INA219s.

Tasks

NameResponsibilityPriority
INA219 TelemetryRead in values from the INA219 and queue the data for processingHigh
Ethernet TransmitTransmit telemetry to other modulesMedium
Data Logging Log sensor telemetryMedium


Callbacks

NameResponsibility
Ethernet ReceiveReceive notification packet to begin logging once liftoff has occurred