- Tool Engineer - John Nash
- Process Engineer - Sean O'Brien
- Super User - Patricia Meller
- Any of these personnel can certify new users
...
Plasma cleans are run before and after depositions to prevent the buildup from peeling off of the chamber.
- A Plasma Clean must be run after every one micron of TEOS Deposition.
- For multiple micron depositions, the wafer must removed after each micron of deposition so that the chamber can be cleaned.
Parameter | Setting |
---|---|
Pressure | 9 Torr |
Power | 250W |
Temp | 390C |
Spacing | 220 mils |
O2 | 285 sccm |
TEOS Flow | 400 sccm |
Deposition Rate | 85 A/sec |
Uniformity | 1.1% |